AFL SMLP5-5-LC - SM/MM Loss Test Kit with Reporting Software
Overview

Description
AFL SMLP5-5-LC-SM/MM is a rugged loss test kit for testing and certifying fiber networks to industry standards. This kit includes an OLS4 quad optical light source and an OPM5 optical power meter. The OPM backlit display is easily viewed in both direct sunlight and dimly lit environments.
OLS4 Quad Source is an integrated two-port LED (850 and 1300 nm) and laser (1310 and 1550 nm) light source designed for performing insertion loss measurements on both multimode and single-mode fiber optic links. Each port can transmit highly stabilized output (single or dual wavelength), ensuring accurate insertion loss test results per current TIA/EIA requirements. Equipped with an industry standard 2 kHz test tone, the OLS4 is an ideal tool to pair with an optical fiber identifier (OFI-BI/PM or OFI-400) for use in fiber identification.
OPM5-2D Optical Power Meter provides accurate power and loss measurements, reference storage for each calibrated wavelength, and detects multiple test tones for fiber identification. A Set-Ref feature allows the OPM5 to display measured power levels relative to a stored, measured level. The OPM5 also provides in-unit data storage. The simple-to-use interface allows for easy separation of test results into files. Integrated file management provides access to results and keeps cable and job results separated for fast customer report generation. Quickly transfer test results to the PC via the USB interface.
Features
- Singlemode loss test kit.
- 850/1300/1310/1550 nm calibrated wavelengths.
- LC connector.
- Includes an OPM5-2D power meter and an OLS4 light source.
- Includes Test Results Manager reporting software (Windows compatible).
- Fiber identification prior to splicing.
- Certify multimode and single-mode links per TIA/EIA standards.
- Auto-detect transmitted wavelengths (reduces errors).
- Test two wavelengths simultaneously (faster testing).
Technical Specifications
Power Meter | ||||
---|---|---|---|---|
Calibrated Wavelengths | 850, 1300, 1310, 1490, 1550 nm | |||
Detector Type | Germanium (Ge) | |||
Measurement Range | +6 to -60 dBm | |||
Tone Detect Range | +6 to -50 dBm +6 to -45 dBm for 850 nm |
|||
Wavelength ID Range | +6 to -50 dBm +6 to -45 dBm for 850 nm |
|||
Accuracy | ±0.25 dB | |||
Resolution | 0.01 dB | |||
Measurement Units | dB, dBm, μW | |||
Light Source | ||||
OLS4 (MM Optical Port) | OLS4 (SM Optical Port) | |||
Wavelength | 850 ±30 nm | 1300 +30/-20 nm | 1310 ±20 nm | 1550 ±20 nm |
Spectral Width | 45 nm (typ) | 120 nm (typ) | 5 nm (max) | 5 nm (max) |
Emitter Type | LED | Laser | ||
Safety Class | Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 | |||
Output Power | >-20 dBm, 62.5 μm multimode | 0 dBm, 9 μm single-mode | ||
Output Stability | ±0.1 dB over 8 hours (after 5 minutes warm-up) |
±0.05 dB over 1 hour (after 15 minutes warm-up) ±0.1 dB over 8 hours (after 15 minutes warm-up) |
||
Tone Output | N/A | 2 kHz | ||
General Specifications | ||||
Adapter Type | LC | |||
Power | 2 AA batteries | |||
Operating Temperature | -10 °C to 50 °C, 90 % RH (non-condensing) | |||
Storage Temperature | -30 °C to 60 °C, 90 % RH (non-condensing) | |||
Dimensions (H × W × D) | 140 mm × 81 mm × 38 mm (5.5 x 3.2 x 1.5 inches) | |||
Weight | 0.29 kg (0.65 lbs) |
User Manual
Download AFL SMLP5-5-LC-SM/MM user manual.
Package Contents
- OPM5-2D Power Meter — 1 pc.
- OLS4 Light Source — 1 pc.
- USB Cable — 1 pc.
- TRM Test Results Manager Software — 1 pc.
- Adapter Caps — 1 set.
- Protective Rubber Boot — 1 pc.
- User Manual — 1 pc.
- Carrying Case — 1 pc.
- AA Batteries — 2 pcs.
- 50 and 62.5 µm Fiber Mandrels — 2 pcs.
- Calibration Certificate — 1 pc.